7.4.1.4 WANPPTP
TheWAN interfacecanbe configuredasPPTP.This type ofconnectionisusuallyusedforaDSL
serviceandrequiresausernameandpasswordtoconnect.
InternetConnectionType:SelectPPPoEfromthedropdownlist.
MTU:TheMaximumTransmissionUnit(MTU)isaparameterthatdeterminesthelargestpacket
size(inbytes)thattherouterwillsendtotheWAN.IfLANdevicessendlargerpackets,therouter
will break them into
smaller packets. Ideally, you should set this to match the MTU of the
connectiontoyourISP.Typicalvaluesare1500bytesforanEthernetconnection.Iftherouter's
MTUissettoohigh,packetswillbefragmenteddownstream.Iftherouter'sMTUissettoolow,
therouterwill
fragmentpackets unnecessarilyandinextremecasesmaybe unabletoestablish
someconnections.Ineithercase,networkperformancecansuffer.
PPTPOptions:SpecifyIPaddress,subnetmask,defaultgatewayandPPTPserver.
Username:SpecifytheusernamewhichisprovidedbyyourISP.
Password: Specifythe
passwordwhich isprovided by your ISP, and then verifyitonce again in
thenextfield.
Type:Selectareconnectiontype:KeepAlive(AconnectiontotheInternetisalwaysmaintained),
Connecton Demand:Youhavetoopen uptheWebbased managementinterfaceandclickthe
ConnectbuttonmanuallyanytimethatyouwishtoconnecttotheInternet.